Changeover Unit CVS
For a perfect dosing result
The supply of chlorine from a dosing system with only one cylinder or battery inevitably leads to failure of the chlorination when empty and requires personnel in order to change cylinders. The CVS meets this demand and also operates without any auxiliary energy whatsoever. For a changeover, it is sufficient for the injector to lower the vacuum below the normal range because of the empty cylinder.
Changeover Unit CVS
- Scope of application with chlorine gas up to 10 kg/h
- For chlorine gas, hydrogen chloride, carbon dioxide or sulphur dioxide
- Compact design
- Safe operation with vacuum technology
- Without auxiliary power
- Without intervention from personnel
- Simple wall mounting
- Optional position feedback via reed relays
- Adjustable switch-point
Further product views
Flow rate with chlorine gas | kg/h | up to 10 | |
---|---|---|---|
Operating pressure | bar | -1 to 0 (vacuum) | |
Switch-point | bar | -0.3 | |
Operating temperature | °C | 0 – 55 | |
Connections | PVC-screw connection DN 15, Hose connection 8/12 or 12/16 | ||
Weight | kg | approx. 1.0 |
Subject to technical changes