Skip to main content
To be able to use the full range of Shopware 6, we recommend activating Javascript in your browser.
Germany
Austria
China
East Asia
France
Germany
Hungary
Middle East
Netherlands
Portugal
Spain
Switzerland
United Kingdom
United States
Italienisch
Deutsch
Spanisch
English (UK)
Portugiesisch
Französisch
Close menu
Your account
Log in
or
sign up
Overview
Your profile
Addresses
Payment methods
Orders
Industry solutions
Applications
Products
System and process technology
Brochures
Service
Contact
Company
Career
Agriculture
Chemical industry
Pharmaceutical industry
Pools
Drinking water treatment
Food & Beverages
Metal & electrical industry
Dosing of chemicals
Water disinfection
Disinfection of swimming and bathing water
Drum and container pumps
Eccentric screw pumps
Diaphragm pumps
Flow meter
Dosing pumps
Chlorinators
Gas dosing devices
Disinfection systems
Centrifugal pumps
Measurement and control technology
Wobble plate pumps
Accessories
Standard systems
Dosing systems and dosing units
System solutions
Download centre
Video library
Request for quotation
Repair service
Repair videos
Software / Firmware
Online calculation assistant
Suction line calculation
Lutz Pumpen contact person
Lutz-Jesco contact person
Lutz Pumpen sales partner
Lutz-Jesco sales partner
Press
Subsidiaries
Group of companies
Trade fair dates
Success stories
Close menu
Show all categories
Suction line calculation
Back
Show Suction line calculation
Service
/
Online calculation assistant
/
Suction line calculation
Industry solutions
Applications
Products
System and process technology
Brochures
Service
Download centre
Video library
Request for quotation
Repair service
Repair videos
Software / Firmware
Online calculation assistant
Contact
Company
Career
Calculation: Diameter of the suction line of a dosing pump
p
Beh
Absolute pressure in the chemical tank
[bar]
(sea level = 1)
p
Dampf
Vapour pressure of dosing agent at valve inlet temperature
[bar]
(Water at 20 °C = 0.023)
H
Saug
Pump suction height
[m]
(>0 at feed, <0 at suction)
Density
Chemical density
[kg/dm
3
]
(Water = 1.0)
Q
Pump delivery capacity
[l/h]
F
Pump stroke frequency
[stroke/min]
L
Length of suction line
[m]
decimal places
NPSH
a
Net Positive Suction Head, available
[bar]
d
Minimum diameter of suction line
[mm]