MINICHLORGEN
Safe, reliable & efficient on-site generation of sodium hypochlorite
MINICHLORGEN sodium hypochlorite systems provide an on-demand supply of <1.0 % sodium hypochlorite solution, generated through the electrolysis of diluted brine solution. Generated in close proximity to the process, the direct storage and dosing of sodium hypochlorite rules out accidental spillage of the sodium hypochlorite and contract with the operating personnel.
MINICHLORGEN
- MINICHLORGEN models available for 30, 60 and 90 g/h chlorine capacity
- Robust and attractive plastic cover
- Vivid LED illumination from the electrolytic chamber offers a presence of the chlorine generation process and at the same time indicating through simple LED colour change the current operational status of the process
- Easy to operate membrane keypad multi-lingual control panel & OLED display with green, amber and red LED operational status indicators
- Operational parameters displayed and code protected programming
- Alarm event log with real time clock recording
- Volumetric flow measurement of water and brine for consistent high efficiency electrolysis
- Safe operation by ambient air monitoring from a hydrogen detector
- Remote transfer of the fault message, data logging & RS485 options
- MINICHLORGEN is supplied with fixings for wall mounting, product tank level switch kit and brine suction assembly
Further product views
MINICHLORGEN | 30 | 60 | 90 | |
---|---|---|---|---|
Chlorine capacity | g/h | 30 | 60 | 90 |
Chlorine concentration* | g/l | 6 | ||
Power consumption | kWh | 0,15 | 0,30 | 0,60 |
Power supply | ø | 110 – 240V | ||
Operating pressure | bar | 2 – 8 | ||
Nominal water consumption* | l/h | 5 | 10 | 15 |
Nominal salt consumption* | kg/h | 0,1 | 0,2 | 0,3 |
Protection class | IP | 54 | ||
Permissible ambient temperature | °C | +5 – +45** | ||
Permissible feed water temperature | °C | +8 – +25*** |
*) standard factory settings
**) in this case, extra venting is required
***) in this case, a water cooler is required
Subject to technical changes