Skip to main content

Chlorinators

With their coordinated components for tasks ranging from chlorination to analysis and warnings, our chlorinators meet all the requirements placed on modern systems. They are distinguished by their reliability and repeated dosing accuracy. Due to their simplicity of use and reliable properties, chlorine and chlorine compounds have been used successfully in water treatment for decades.

High-quality chlorinators for optimum disinfection and water quality


In the area of gas-conveying technology, we have specialised in chlorine gas dosing. However different the requirements are, our comprehensive range of well-proven units can deliver doses of chlorine gas under vacuum conditions, or liquid chlorine compounds. Our systems are designed according to DIN 19606 and EN standards and ensure optimum water quality through precisely measured disinfection. We use our know-how and experience to find the best solution - technically and scientifically. The quality of our precision equipment and our expertise are vital to our customers’ success.

Increasing water usage in public, industrial and domestic applications has established water treatment for reuse as an imperative. As the last stage in the treatment process, disinfection is particularly important. Reliable dosing systems are necessary for responsible addition of disinfectants to water. To this end, we have conducted research and development in this area to produce world-leading system solutions. For the disinfection of drinking water, swimming and wading pool water, process water, cooling water and waste water, different methods are used. These differ in their technical design and the type of chemicals used.

Everything for your chlorine gas dosing needs: vacuum regulators, chlorinators and safety equipment

Vacuum regulators and chlorinators

To the products

Chlorine gas under pressure

To the products

Chlorine gas under vacuum

Chlorine gas under vacuum

Safety technology for chlorine gas

To the products

Accessories

To the products

Application examples for efficient chlorination with Lutz-Jesco chlorinators

Application examples for efficient chlorination with Lutz-Jesco chlorinators Small-size chlorinators with gas take-off of up to 10 kg Cl2/h

The fact that our products were designed for small dosing quantities makes them ideal for the disinfection of swimming pool water, providing maximum safety in the process. They work with total vacuum, directly from a chlorine tank. Even if there is mechanical damage to the highly chemical-resistant plastic pipes and units, no chlorine gas can escape. The devices can be mounted on cylinders and are equipped with a residual pressure safety device for the compressed gas tank. A pressure gauge for the cylinder pressure with double safety effected by a diaphragm pressure transmitter is provided as standard.

Open exposés

Large-scale chlorinators with a gas take-off up to 200 kg Cl2/h

Our dosing systems ensure top quality and maximum safety for large quantities of chlorine. The dosing devices work with extremely high precision at both positive and negative pressure, and embody Lutz-Jesco's many years of experience in the handling of chlorine gas. Our products for large dosing quantities find particular application in the centralised treatment of drinking water.

Open exposés

Our complete range of chlorinators

Filter
Motive Water Set
Description:For a perfect dosing result Motive water sets are preassembled fittings in various configuration levels and used in combination with booster pumps to guarantee a constant supply pressure for chlorine gas ejectors. The pressure reducing valve is the most important part of the motive water unit. It compensates all pressure fluctuations in the booster pump.Features & advantages: Pre-assembled fixture Constant supply pressure for ejectors Max. flow rate 24 m³/h Nominal width DN 15DN 32DN 50 Max. flow ratem3/h 3624 Pressure reducer setting rangebar 1.5...6.0 Max. supply pressurebar 16 Pressure reducer equipment Pressure gauge 0...10 bar, Ø63 mmStrainer Material for shutoff valve, pressure reducer, solenoid valve Red brass Material for non-return valve PVC / FPM / Hastelloy Max. operating pressure°C 40 Solenoid valve 230 V, 50/60 Hz Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Treibwassersatz-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Motive_water_set-EN-PI.pdf
Electric Changeover Unit C 7522
Description:For a perfect dosing result The C 7522-type chlorine changeover unit ensures the uninterrupted supply of chlorine. It has been designed for the use in vacuum-type chlorination installations. The chlorine can be liquid or gaseous. The C 7520-type changeover unit consists of two independent, electrical motor-driven ball valves, a contact pressure gauge and an electronic control.Features & advantages: Plate mounted design Emptying of residues Peak mode Manual control Empty status signal Malfunction alert Output with chlorine gaskg/h up to 100 Connections DN 25 / PN 16, PVC-bonded socket joint Ø32 Power supply 230 V AC, 50/60 Hz Engine ball valves 2, DN 25, with manual control Contact vacuum gauge NG 63, -1...0 bar Control for the empty and malfunction signal Position indicator and relay Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vakuum_Chlorumschaltung_C7522-DE-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vakuum_Chlorumschaltung_C7522-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C7522-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vacuum_Chlorine_Changeover_C7522-EN-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vacuum_Chlorine_Changeover_C7522-EN-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C7522-EN-PI.pdf
Chlorinator C 2525-MH
Description:Dosing chlorine gas in larger amounts Chlorine dosing units of group C 2525-MH operate as full vacuum equipment and are employed mainly in water works for municipal and industrial water supply and waste water treatment. The units consist of functional elements of modular design and are characterized by high operational safety. The chlorinators are available in a wall mounted version and a floor mounted cabinet version.Features & advantages: Flow rates 5/10/15/25 kg/h Cl2 Vacuum technology according to DIN 19606 Manual or automatic control Wall mounted or cabinet type Dosing rangeskg Cl2/h up to 25 Operating vacuummbar -100 Required ejector vacuummbar -250 Flow adjustment range% 0...100 Flow meterLengthmm 300 Accuracy% ± 2 FSD Scale ratio 1:20 Material Glass Vacuum gaugeRangebar -1...0 Sizemm Ø63 Accuracy% ± 2.5 FSD Materials of construction in contact with chlorinePlastics PVC Springs Hastelloy Sealings, Diaphragm FPM Weight (with C 7700)WL-typekg 12.5 SL-typekg 37 Ambient temperature°C 0...40 (no direct sun light) Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C2525_MH-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C2525_MH-EN-PI.pdf
More Chlorine Gas Accessories
Description:For a perfect dosing result Useable in many applications: cylinder support, sprinkler systems, scrubber, room heater, emergency equipment, eyes and body shower.Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Sprinkler_Anlagen-DE-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Wand_Anschlussblock-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Sprinkler_Systems-EN-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Wall_Connection_Block-EN-MB.pdf
Reaction Tower
Description:For a perfect dosing result If the pool water constantly circulating and also used for the ejector operation is very soft, artificial hardness must be produced in order to avoid an inadmissible reduction of the pH value. This problem can be solved easily by using a hypochloric acid reaction tower, in which the hydrochloric acid is neutralized completely by means of granulated marble.Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Reaktionsturm_Unterchlorigsaeure-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Reaction_Tower_Hypochloric_Acid-EN-MB.pdf
Ejectors / Non Return Valves
Description:For a perfect dosing result A characteristic feature of chlorination systems to DIN 19606 is that the chlorine gas to be metered is maintained at subatmospheric pressure and therefore in a range which is proof against leakages. Any leaks would merely cause air to enter the system, but would not allow chlorine gas to escape.Features & advantages: Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Standard_Injektoren-DE-MB-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Gross_Injektoren-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Injektor_Rueckschlagventil-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Standard_Injektoren-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Injektor_R%C3%BCckschlagventil-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Standard_Ejector-EN-MB-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Large_scale_Ejectors-EN-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Injector_Non_Return_Valve-EN-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Standard_injectors-EN-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Injector_non_return_valve-EN-PI.pdf
Vacuum regulator C 2214
Description:For a perfect dosing result The full-vacuum chlorinator used as pressure reducing valve is of central importance for the safety in vacuum installations. For this reason the C 2214 version has been designed in accordance with the latest findings. The device combines several functions in one housing.Features & advantages: Output with chlorine gas: up to 4 kg/h Gas filter Safety relief valve Flow meter with manual setting Residual pressure safety device Output with chlorine gas 4 g/h ... 4 kg/h Inlet pressurebar max. 16 Pressure connection Union nut BSW 1“ Connection vacuum Hose clamp 8/12 Inlet valve material Monel, brass, Hastelloy Casings material PVC Membrane material FPM Manometerbar -1...15 Empty status signal via the contact manometer alternative to manometer Dimensions (W x H x D)mm 129 x 225 x 237 Weightkg approx. 2.7 Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-C2214-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C2214-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-C2214-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C2214-EN-PI.pdf
Activated Carbon Cartridge
Description:Avoiding of faulty alarms Activated carbon cartridges are generally used in vacuum chlorine gas systems. In almost any system, temporary shock pressures may occur in the vacuum system, which cause the extremely sensitive safety blow-off valve to respond briefly so that the gas warning device is activated. To ensure that only an "actual" dangerous situation is indicated by the gas warning device, an activated carbon cartridge is integrated in the blow-off pipe, thus avoiding faulty alarms.Features & advantages: Incorrect messages are avoided Leakages can be detected by the hose Simple installation Long service life Low maintenance effort Casings material PVC Seals FKM Content 0.9 l activated carbon (Ø2 mm) Connection Hose clamp connection 6/8 or 8/12 Weightkg approx. 1.2 Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Aktivkohle_Patrone-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Activated_carbon_cartridge-EN-PI.pdf
Electric Changeover Unit C 7522
Description:For a perfect dosing result The C 7522-type chlorine changeover unit ensures the uninterrupted supply of chlorine. It has been designed for the use in vacuum-type chlorination installations. The chlorine can be liquid or gaseous. The C 7520-type changeover unit consists of two independent, electrical motor-driven ball valves, a contact pressure gauge and an electronic control.Features & advantages: Plate mounted design Emptying of residues Peak mode Manual control Empty status signal Malfunction alert Output with chlorine gaskg/h up to 100 Connections DN 25 / PN 16, PVC-bonded socket joint Ø32 Power supply 230 V AC, 50/60 Hz Engine ball valves 2, DN 25, with manual control Contact vacuum gauge NG 63, -1...0 bar Control for the empty and malfunction signal Position indicator and relay Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vakuum_Chlorumschaltung_C7522-DE-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vakuum_Chlorumschaltung_C7522-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C7522-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vacuum_Chlorine_Changeover_C7522-EN-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vacuum_Chlorine_Changeover_C7522-EN-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C7522-EN-PI.pdf
Injection Nozzles Chlorine
Description:For a perfect dosing result The injection nozzles for chlorine are appropriately combined fittings via which the chlorine solution (hypochloric acid) supplied by the full-vacuum chlorinators is introduced into the water to be treated. The injection nozzle assembly comprises an injection pipe which is screwed into the water pipe, a shutoff valve and a non-return valve.Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Impfstellen_Chlorloesung-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Injection_Nozzles_Chlorine_Solution-EN-MB.pdf
Vacuum regulator C 2213
Description:For a perfect dosing result The full-vacuum chlorinator used as pressure reducing valve is of central importance for the safety in vacuum installations. For this reason the C 2213 version has been designed in accordance with the latest findings. The device combines several functions in one housing.Features & advantages: Output with chlorine gas: 25 g/h up to 10 kg/h Compact design Safe operation with vacuum technology Flow limiter Gas filter Available with all current gas connections Can be connected directly to gas bottles or collecting pipes Output with chlorine gas 25 g/h up to 10 kg/h (with flow limiter <1 kg/h) Inlet pressurebar max. 16 Pressure connection Union nut BSW 1“ Vacuum connection Hose clamp Ø 8/12 Inlet valve material Monel, brass and Hastelloy Casings material PVC Membrane material FPM Manometerbar -1...15 Empty status signal with the contact manometer alternative to manometer Dimensions (W x H x D)mm 108 x 218 x 169 Weightkg approx. 2.3 Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-C2213-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C2213-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-C2213-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C2213-EN-PI.pdf
Expansion Systems
Description:Safety along the entire line Liquid chlorine expands strongly when heated and can create extremely high pressure as a result. Consequently, all line systems for liquid chlorine must be equipped with a expansion system. Expansion systems consist of a rupture disk, a contact pressure gauge as well as an optional relief valve. The integrated contact pressure gauge indicates and provides for remote signalling of the failure.Features & advantages: Response pressure 22.5 bar Consisting of a rupture disk and contact pressure gauge Available with optional relief valve Expansion tanks as optional accessories Long service life Low maintenance effort Rupture disk Material MONEL Response pressurebar 22.5 at 20 °C21.8 at 50 °C20.9 at 100 °C Tolerance% ± 10 Vacuum-resistant yes Nominal width DN25 Relief valve Material C-steel Response pressurebar 27.5 Tolerance% ± 10 Nominal width DN12.5 Pressure gauge Material Steel / Silver / FPM Nominal sizemm Ø 63 Accuracy% ± 2.5 Contact load rating 50 V / 0.5 A / 10 W Weight rupture disk with contact pressure gauge and relief valvekg 10.3 Weight rupture disk with contact pressure gaugekg 8.6 Description Order no. Flexible connection pipe 2 mwith G 5/8 lock nuts on both sides 88566 Chlorine cylinder 10 dm³ with wall holderConnection thread G 5/8 a 22100065 Chlorine cylinder 20 dm³ with wall holderConnection thread G 5/8 a 22100066 Description Order no. Rupture disk DN2522.5 bar, MONEL 23900002 Relief valve DN12.527.5 bar1/2" NPT male - 1/2" NPT female 22800004 Contact pressure gauge 0...40 barØ 63 mm, connection 1/4" NPT maleContact closed and de-pressurised 24000026 Maintenance kit for expansion system2 flange gaskets, O-ring for rupture disk,2 flat gaskets for connection G 5/8 40886 Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Expansionssysteme-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Expansion_systems-EN-PI.pdf
Chlorine Evaporator C 6100
Description:For a perfect dosing result The chlorine evaporator C 6100 has a heating element which in a simple and economical method converts up to 220 kg/h of liquid chlorine into chlorine gas. Chlorine evaporators are mainly used in water treatment plants of cooling water systems for power plants, large factories, petrochemical installations as well as waste water treatment plants.Features & advantages: Evaporator output of up to 220 kg Cl2/h Evaporation coil design with water as a heating medium Hot water tank and evaporation coil made of seamless pressure tank steel Electrical heating of the water using immersion heaters Sensors for monitoring the temperature, pressure and fill level Visual indicators for pressure, fill level and temperature Cathodic anti-corrosion protection Evaporation coil volume (model variant) 1,8 dm38,3 dm3 Evaporator capacitykg/h 65220 Heating capacitykW 2 x 54 x 5 Volume of warm water tankLitres 175 Voltage supply 230/400 V, 50/60 Hz Contact load ratingContact thermometer Max. 250 V, max. 1 A, 30 W Contact pressure gauge Temperature monitoring Max. 250 V, max. 2 A Chlorine connection (inlet and outlet) Flange DN25/PN40 that complies with EN 1092 Form D (groove) Permissible ambient temperature°C 0 – 50 Hydrostatic test pressurebar 60 Operating pressurebar 40 (100 °C) Weightkg 275 Control cabinet for chlorine evaporator Voltage supplykg 3x 400 V (-15%) 50 Hz (±1%) Power consumptionA max. 50 Control voltage 24 V DC / 24 V AC Housing material Sheet steel, painted Protection class IP55 Weightkg 50 approx. Ambient temperature°C 0 – 50 (no direct sunlight) Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlorverdampfer_C_6100-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-C6100-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Schaltschrank_Chlorverdampfer-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlorine_Evaporator_C_6100-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-C6100-EN-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Control_cabinet_C6100-EN-PI.pdf
Changeover Unit CVS
Description:For a perfect dosing result The supply of chlorine from a dosing system with only one cylinder or battery inevitably leads to failure of the chlorination when empty and requires personnel in order to change cylinders. The CVS meets this demand and also operates without any auxiliary energy whatsoever. For a changeover, it is sufficient for the injector to lower the vacuum below the normal range because of the empty cylinder.Features & advantages: Scope of application with chlorine gas up to 10 kg/h For chlorine gas, hydrogen chloride, carbon dioxide or sulphur dioxide Compact design Safe operation with vacuum technology Without auxiliary power Without intervention from personnel Simple wall mounting Optional position feedback via reed relays Adjustable switch-point Flow rate with chlorine gaskg/h up to 10 Operating pressurebar -1 to 0 (vacuum) Switch-pointbar -0.3 Operating temperature°C 0 – 55 Connections PVC-screw connection DN 15, Hose Connection 8/12 or 12/16 Weightkg approx. 1.0 Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-CVS-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-CVS-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-CVS-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-CVS-EN-PI.pdf
Chlorinator C 2700-V
Description:Dosing chlorine gas in larger amounts To avoid the risk of chlorine leakage all pipings and devices downstream of the vacuum regulator are below atmospheric pressure. In case of leakage air is sucked into the system, but no chlorine escapes into the atmosphere.Features & advantages: Flow rate with chlorine gas: up to 200 kg/h Safe operation with vacuum technology Included relief valve Highly resistant materials Optional pressure gauge Flow rate with chlorinekg/h up to 200 Inlet pressurebar 1.5...16 Operation vaccummbar -50 Relief pressurembar 500 Pressure gauge (optional)bar / mm 0...16 / Ø63 Materials of constructionInlet valve Nickel plated brass, ceramic, Hastelloy Vacuum part PVC Sealings FPM, PTFE Weight (with flange and pressure gauge)kg 8 Ambient temperature°C 0...40 (no direct sun light) Description Order no. Flange DN 25 / PN 40 with tongue acc. EN1092 shape CThreaded flange 1" NPT female 15927 Weld neck flange Ø33.7 x 4 mm 39516 Liquid sealing compound 50 ml for bonding of 1” NPT-threads     Ammonia solution 50 ml for leakage test 13514 8/12 mm PE tubing for relief valve 97124 Description Order no. Small maintenance kit (for annual service) gaskets, valve seat, screws, flange gasket, rubber hose for relief valve 39511 Large maintenance kit (after 3 years) includes small maintenance kit, diaphragm, valve cone, spring 39512 Maintenance kit for diaphragm disc: Diaphragm, screws, rubber hose for relief valve (included in the large maintenance kit) 39513 Pressure gauge 0...16 bar connection 1/4” NPT male (Replacement is recommended after 5 years of use) 24087599 Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlorgas_Vakuumregler_C_2700_V-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C2700_V-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Vacuum_regulator_for_chlorine_gas_C_2700_V-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C2700_V-EN-PI.pdf
Safety Blow Off Valves
Description:Reduction of excess pressure in vacuum lines The safety valve prevents a vacuum builds up in a pressure line system, which could otherwise lead to undesired chlorination. It opens at the lowest excessive pressure and discharges the piping system. The end of the blowdown pipe is run near the gas sensor.
Booster Pumps
Description:For a perfect dosing result Booster pumps have been designed especially for use in chlorination installation (according to German standard DIN 19606). This standard specifies that the chlorine gas must be dissolved in water under vacuum. To produce the vacuum ejectors (water-jet pumps) are used. The booster pumps ensure that a sufficient amount of motive water is supplied to the ejectors at the required pressure. Booster pumps have to be selected in accordance with the operating data of the ejectors.Features & advantages: Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Druckerhoehungspumpe-DE-PI_01.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Booster_Pump-EN-PI_01.pdf
Safety Shutoff Valves
Description:Double safety for vacuum lines Contact a broken vacuum line and a leaky vacuum regulator on simultaneously, uncontrolled escape of chlorine gas. The safety shutoff valve prevents this from happening, ensuring the highest possible level of safety. The shutoff valve also prevents water penetration into the vacuum controller if the injector check valve is leaky.Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Sicherheits_Sperrventil-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Safety_Shutoff_Valve-EN-MB.pdf
Catchpot
Description:Protects against liquid chlorine Liquid chlorine may cause major contamination in vacuum regulators and also cause damage to the PVC in parts. Therefore the penetration of liquid chlorine into the units must be avoided and we recommend using a catchpot to protect the dosing units.Catchpots are vertically positioned containers where liquid chlorine is collected. Liquid chlorine is slowly evaporated by the energy in the atmosphere or by means of a heating sleeve which heats up the catchpot.Features & advantages: Protects the vacuum regulator against small amount of liquid chlorine Suitable for drum and wall mounting Heating sleeves as an optional accessory Long service life Low maintenance effort Nominal pressure PN25 Weight125 mlkg approx. 3 250 mlkg approx. 3 (+ approx. 1 kg per flange) 1000 mlkg approx. 8 Max. operating temperature°C 50 Housing material Carbon steel Heating sleeves Order no. for 1" steel pipes suitable for catchpots of up to 250 mlwith a 3 m cable and mounting material25 W, 240 V 40499 25 W, 120 V 40498 for 2" steel pipes suitable for catchpots of uo to 1000 mlwith a 3 m cable and mounting material30 W, 240 V 40204 30 W, 120 V 40205 Flanges DN25 / PN40 with groove / tongue according to EN 1092-1 Order no. Weld neck flangeTongue flange 39516 Groove flange 39517 Threaded flange1" NPT female flangeTongue flange 15927 Groove flange 15928 Assembly accessories for flangesscrews, nuts, washers, seals(assembly accessories are included in the catchpot) 38712 Auxiliary valvesfor connection to the valve of the pressure container Order no. Output: Threaded pin BSP 5/8Inputaccording to the standard BSW 1"DIN 477 22338693 BSP 5/8BS 341 22338694 BSP 3/4AS 2473 22338695 1.030" x 14NGOCGA V-1 (660) 22338696 YOKECGA V-1 (820) 22338697 BSW 1 1/4"DIN 4676 22338698 M26x3- 22300065 Key for operation of auxiliary valves 38684 Flexible connecting line2 m long, with BSP 5/8 union nut on both sidesConnection between auxiliary valve and wall-mounted catchpot 88566 Connection seals at the input Order no. Threaded pin BSP 5/8 81832 Union nut BSW 1" 81043 Union nut BSW 1 1/4" 81835 Flange DN25 / PN40 with groove / tongue 81421 Connection seals at the output Order no. Universal head BSP 5/8 81832 Threaded pin BSP 3/4 81833 Threaded pin BSW 1" 81834 Threaded pin 1.030" x 14NGO 81836 Flange DN25 / PN40 with groove / tongue 81421 Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Tropfenabscheider-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Tropfenabscheider-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Catchpot-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Catchpot-EN-PI.pdf
Chlorine Gas Filter
Description:For a perfect dosing result Proper operation of chlorine gas dosing equipment in chlorine gas systems can be ensured only if they are protected against impurities. With the chlorine gas filter, a product is available that removes impurities such as particles and chlorine condensates from the inflowing chlorine gas. Inside the chlorine gas filter, there is a ceramic filter element, on the surface of which the impurities are deposited when the gas flows through the filter.Features & advantages: Max. flow rate: 200 kg Cl2/h Robust, simple design Low maintenance effort Housing made of thick-walled steel Flow rate at 2 barkg Cl2/h 100 Flow rate at 6 barkg Cl2/h 200 Max. operating pressurebar 40 Max. operating temperature°C 80 Housing material C-steel Connections Flange DN25 / PN40 with groove (inlet) andtongue (outlet) according to EN 1092-1 Sealing material FPM, Klingersil Filter material Ceramic Dimensions (W x H x D)mm 305.5 x 330 x 165 Weightkg approx. 20 Description Order no. Counter flange – 1" NPT female thread with tongue 15927 Counter flange – 1" NPT female thread with groove 15928 Counter flange – welding neck flange with tongue 39516 Counter flange – welding neck flange with groove 39517 Heating, 240 VAC 50/60 Hz, 30 W, without plug 40204 Heating, 120 VAC 50/60 Hz, 30 W, without plug 40205 Description Order no. Spare parts kit (replacement filters and seals) 40206 Mounting kit for flange DN25 38712 Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlorgasfilter-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Chlorgasfilter-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlorine_gas_filter-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Chlorine_gas_filter-EN-PI.pdf
Ejectors / Non Return Valves
Description:For a perfect dosing result A characteristic feature of chlorination systems to DIN 19606 is that the chlorine gas to be metered is maintained at subatmospheric pressure and therefore in a range which is proof against leakages. Any leaks would merely cause air to enter the system, but would not allow chlorine gas to escape.Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Standard_Injektoren-DE-MB-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Gross_Injektoren-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Injektor_Rueckschlagventil-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Standard_Injektoren-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Injektor_R%C3%BCckschlagventil-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Standard_Ejector-EN-MB-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Large_scale_Ejectors-EN-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Injector_Non_Return_Valve-EN-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Standard_injectors-EN-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-Injector_non_return_valve-EN-PI.pdf
Control Valve C 7700
Description:For a perfect dosing result The chlorine gas flow is rarely controlled by hand in state-of-the-art chlorination installations according to DIN 19606. In the majority of cases, the concentration of free chlorine in the water is monitored by an electronic controller which sets the required chlorine gas quantity by means of an electrically operated valve.Features & advantages: 3-phase switch or 4 – 20 mA Linear characteristic Mounted on wall plates Manually lockable at 100 % opening Flow rate with chlorine gaskg/h up to 200 Position feedbackOhm 1000 Power supply 230 V, 50 – 60 Hz, or 24 V Control 3-phase switch (with 230 V), 4 – 20 mA (with 24 V) Protection class IP55 Measurementsmm 320 x 660 Flow meter with manual setting (optional) 4 g/h – 4 kg/h (with chlorine gas) Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlor_Regelventil_C7700-DE-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlor_Regelventil_C7700-DE-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C7700-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlorine_Control_Valve_C7700-EN-BW.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg2/LJ-Chlorine_Control_Valve_C7700-EN-MB.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-C7700-EN-PI.pdf
Flow Meter
Description:For a perfect dosing result Useable in many applications.
Lifting Beam / Crane Balance
Description:For a perfect dosing result Useable in many applications.
Your contact person
Lutz-JESCO America Corp.
Do you have questions about dosing pumps, disinfection systems, chlorine dosing systems, system and process technology or measurement and control technology?
Our team of experts will be happy to assist you. Please send us an enquiry or call us directly.
+1 5854260990