Select a category
Our complete range of water sampling stations
Water Sampling Station EASYPRO Drinking water and Bathing water
Description:Controlled disinfection The EASYPRO water sampling station enables standard-conform and continual measurement of the process water in public swimming pools, industrial plant and hot water installations up to 65 °C. The exact dosing of the disinfectant requires the constant measurement of the process water and the exact control of the dosing system. The modular design of the water sampling station enables its exact adaptation to suit your needs. -->Features & advantages: EASYPRO SMART components (fitted on the baseplate) TOPAX® MC multi-channel controller Peristaltic pumps Measuring cell fittings Flow control Flow adjustment valve Sampling water extraction point Temperature sensor Inflow and outflow tap Buffer solutions for adjusting the measuring cells Suction lines (not installed on the baseplate) Injection nozzles (not installed on the baseplate) The measuring cells are partially packaged separately and not pre-installed. EASYPRO SMART for swimming pools CP RP CPL Dimensions (W x H x D)mm 454 x 465 x 167 approx. Sample water requirementl/h 45 approx. Sample water infl ow and discharge Stop valve with hose clamp connector 6/8 Pressure resistancebar max. 3 Pressure loss in the water sampling stationbar 0.3 approx. Voltage supply 100 – 240 V AC, 50/60 Hz Power consumptionW max. 30 Analogue outputs for remote transmission 4 x 0/4 – 20 mA, working resistance max. 500 Ω Disturbance variable inputmA 0/4 – 20 Interfaces Ethernet TCP/IP or RS485 Modbus RTU (optional) Protection class IP65 (electronic controller) Ambient temperature°C -5 to +45 (no exposure to direct sunlight) Control characteristic P, PI, PID or PD behaviour, control direction selectable with distur-bance variable feed forward, 2-side control selectable Measuring inputs (depending on version) Number of measuring inputs 2a 3b Free chlorineCS120 excess chlorine measuring cellmg/l 0 – 15c - 0 – 15c pH valuepH single-rod measuring cellpH 2 – 12d or 0 – 14d Redox valueRedox single-rod measuring cellmV - 0 – 1000 - Conductivity conductiveConductivity measuring cell (k=1)mV - 0 – 2e, 0 – 20e or 0 – 100e TemperaturePt100°C 5 – 45 Output modules (depending on version) Number of output modules up to 4 Servomotor relay 2 x 230 V AC, 5 A (ohmic load) kΩ Potentiometer feedback: 1 – 10 Servomotor 20 mA Constant 0/4 – 20 mA output Servomotor with 20 mA feedback Relay 2 x 230 V AC, 5 A (ohmic load) Optocoupler 2 x 80 V DC, 5 mA Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-EASYPRO-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-EASYPRO-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-EASYPRO-Schwimmbad-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-EASYPRO-pool-EN-PI.pdf
Water sampling station EASYPRO SMART
Description:Reliable and individual Designed to meet your every need, the EASYPRO system monitors and controls a range of water parameters in your swimming pool. The TOPAX® MC multi-channel controller installed in the EASYPRO subjects the water parameters to constant measurement, keeping them within the target range. It enables you to control a large number of actuators and permits easy and intuitive Operation. The multi-coloured LEDs provide an optical warning if the water parameters leave the target range. -->Features & advantages: EASYPRO components (fitted on the baseplate): TOPAX® MC multi-channel controller Measuring cells and measuring cell fittings Sample water filter Flow control Flow controller DFR 45 with sampling water extraction point and installed temperature sensor Inflow and outflow tap Bracket for buffer solutions and buffer solutions for adjusting the measuring cells Multi-coloured LEDs Cover The measuring cells are partially packaged separately and not pre-installed. EASYPRO for swimming pools MB-C ME-C MC-C MD-C MP-C MK-C MBB-C MEE-C Dimensions (W x H x D)with covermm 500 x 530 x 117 approx. 500 x 933 x 128 approx. - - without covermm 490 x 490 x 117 approx. 490 x 900 x 117 approx. 900 x 490 x 117 approx. 900 x 490 x 117 approx. Sample water requirementl/h 30 approx. 2 x 30 approx. Sample water inflow and discharge PE hose 6/8 + stop valve with G1/4 connection Pressure resistancebar max. 6 max. 6, air gap required max. 6 Pressure loss in the water sampling stationbar 0.3 approx. 2 x 0,3 approx. Mesh size sample water filterµm 300 Voltage supply 100 – 240 V AC, 50/60 Hz Power consumptionW max. 20 Analogue outputs for remote transmission x 0/4 – 20 mA, working resistance max. 500 Ω Disturbance variable inputmA 0/4 – 20 Interfaces Ethernet TCP/IP or RS485 Modbus RTU (optional) Protection class IP65 (electronic controller) Ambient temperature°C -5 to +45 (no exposure to direct sunlight) Control characteristic P, PI, PID or PD behaviour, control direction selectable with disturbance variable feed forward, 2-side control selectable v inputs (depending on version) Number of measuring inputs 2a 3b 4c 3b 2 x 1 2 x 2a Free chlorinemperometric 3-electrode measuring cell with potentiostat (DMZ3.1)mg/l 0 – 15 d - 0 – 15d - 0 – 15 d 2 x 0 – 15 - Diaphragm-covered measuring cellmg/l - - - 0 – 10e - - Total chlorineDiaphragm-covered measuring cellmg/l - - - - 0 – 10e - pH valuepH single-rod measuring cellpH 2 – 12f or 0 – 14f 2 x 2 – 12f or 2 x 0 – 14f Redox valueRedox single-rod measuring cellmV - 0 – 1000 - 2 x 0 – 1000 Conductivity conductiveConductivity measuring cell (k=1)mS/cm - 0 – 2g),0 – 20g) or 0 – 100g) - TemperaturePt100°C 5 – 45 2 x 5 – 45 Output modules (depending on version) Number of output modules up to 4 Servomotor relay 2 x 230 V AC, 5 A (ohmic load) kΩ Potentiometer feedback: 1 – 10 Servomotor 20 mA Constant 0/4 – 20 mA output Servomotor with 20 mA feedback Relays 2 x 230 V AC, 5 A (ohmic load) Optocoupler 2 x 80 V DC, 5 mA Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-EASYPRO_SMART-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-EASYPRO_SMART-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-EASYPRO-SMART-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-EASYPRO-SMART-EN-PI.pdf
Water sampling station EASYPRO COMPACT
Description:Zuverlässig und individuell Mit der EASYPRO erhalten Sie ein komplett auf Ihre Bedürfnisse abgestimmtes System zur Überwachung und Regelung verschiedener Wasserparameter in Ihrem Schwimmbad. Durch den auf der EASYPRO verbauten Mehrkanalregler TOPAX® MC werden die Wasserparameter kontinuierlich gemessen und im Sollbereich gehalten. Er bietet die Möglichkeit eine Vielzahl von Aktoren und Stellgliedern anzusteuern und zeichnet sich durch seine sehr einfache und intuitive Bedienung aus. Die mehrfarbigen LEDs sorgen für eine optische Warnung, wenn die Wasserparameter den Sollbereich verlassen. -->Features & advantages: EASYPRO COMPACT components (fitted on the baseplate): TOPAX® MC multi-channel controller Measuring cell fittings Sample water filter Flow control Flow controller DFR 45 with sampling water extraction point Temperature sensor Inflow and outflow tap Bracket for buffer solutions and buffer solutions for adjusting the measuring cells EASYPRO COMPACT for swimming pools EASYPRO COMPACT Dimensions (W x H x D)mm 454 x 496 x 161 approx. Sample water requirementl/h 30 approx. Sample water infl ow and discharge PE hose 6/8 + stop valve with G1/4 connection Pressure resistancebar max. 6 Pressure loss in the water sampling stationbar 0.3 approx. Mesh size sample water fi lterµm 300 Voltage supply 100 – 240 V AC, 50/60 Hz Power consumptionW max. 20 Analogue outputs for remote transmission 4 x 0/4 – 20 mA, working resistance max. 500 Ω Disturbance variable inputmA 0/4 – 20 Interfaces Ethernet TCP/IP or RS485 Modbus RTU (optional) Protection class IP65 (electronic controller) Ambient temperature°C -5 to +45 (no exposure to direct sunlight) Control characteristic P, PI, PID or PD behaviour, control direction selectable with distur-bance variable feed forward, 2-side control selectable v inputs (depending on version) Number of measuring inputs 3* Free chlorineAmperometric 3-electrode measuring cell with potentiostat (DMZ3.1)mg/l 0 – 15 (dependant on the measuring cell transconductance) pH valuepH single-rod measuring cellpH 2 – 12 or 0 – 14(depending on the single-rod measuring chain) Redox value Redox single-rod measuring cellmV 0 – 1000 TemperaturePt100°C 5 – 45 Output modules (depending on version) Number of output modules up to 4 Relay 2 x 230 V AC, 5 A (ohmic load) Optocoupler 2 x 80 V DC, 5 mA Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-EASYPRO_COMPACT-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-EASYPRO-COMPACT-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-EASYPRO-COMPACT-EN-PI.pdf
Water sampling station EASYPRO Industry
Description:Zuverlässig und individuell Mit der EASYPRO erhalten Sie ein komplett auf Ihre Bedürfnisse abgestimmtes System zur Überwachung und Regelung verschiedener Wasserparameter in Ihrem Schwimmbad. Durch den auf der EASYPRO verbauten Mehrkanalregler TOPAX® MC werden die Wasserparameter kontinuierlich gemessen und im Sollbereich gehalten. Er bietet die Möglichkeit eine Vielzahl von Aktoren und Stellgliedern anzusteuern und zeichnet sich durch seine sehr einfache und intuitive Bedienung aus. Die mehrfarbigen LEDs sorgen für eine optische Warnung, wenn die Wasserparameter den Sollbereich verlassen. -->Features & advantages: EASYPRO components (fitted on the baseplate) TOPAX® MC multi-channel controller Measuring cells and measuring cell fittings Sample water filter Flow control Flow controller DFR 45 with sampling water extraction point and installed temperature sensor Inflow and outfl ow tap Bracket for buffer solutions and buffer solutions for adjusting the measuring cells Multi-coloured LEDs Cover The measuring cells are partially packaged separately and not pre-installed. EASYPRO for industrial applications 1 2 3 4 1/1 2/2 Dimensions (W x H x D)with covermm 500 x 530 x 117 approx. 500 x 933 x 128 approx. - - without covermm 490 x 490 x 117 approx. 490 x 900 x 117 approx. 900 x 490 x 117 approx. 900 x 490 x 117 approx. Sample water requirementWith CS120 excess chlorine measuring celll/h 45 approx. - With all other measuring cells 30 approx. 2 x 30 approx. Sample water inflow and discharge PE hose 6/8 + stop valve with G1/4 connection Pressure resistanceWith diaphragm-covered measuring cellbar max. 6, air gap required With all other measuring cells max. 6 Pressure loss in the water sampling stationbar 0,3 approx. Mesh size sample water filterµm 300 Voltage supply 100 – 240 V AC, 50/60 Hz Power consumptionW max. 20 Analogue outputs for remote transmission 4 x 0/4 – 20 mA, working resistance max. 500 Ω Disturbance variable inputmA 0/4 – 20 Interfaces Ethernet TCP/IP or RS485 Modbus RTU (optional) Protection class IP65 (electronic controller) Ambient temperature°C -5 to +45 (no exposure to direct sunlight) Control characteristic P, PI, PID or PD behaviour, control direction selectable with disturbance variable feed forward, 2-side control selectable v inputs (depending on version) Number of measuring inputs 1 2a) 3b) 4c) 2 x 1 2 x 2a) BromineDiaphragm-covered measuring cellmg/l 0 – 5e) - Free chlorineAmperometric 3-electrode measuring cell with potentiostat (DMZ3.1)mg/l 0 – 15d) 2 x0 – 15d) CS120 excess chlorine measuring cellmg/l 0 – 10d) - Diaphragm-covered measuring cellmg/l 0 – 10e) - Chlorine dioxideAmperometric 3-electrode measuring cell with potentiostat (DMZ3.1)mg/l 0 – 15d) - CS120 excess chlorine measuring cellmg/l 0 – 10d) - Diaphragm-covered measuring cellmg/l 0 – 2e) - Total chlorineDiaphragm-covered measuring cellmg/l 0 – 10e)) - OzonMembranbedeckte Messzellemg/l 0 – 2e) - pH valuepH single-rod measuring cellpH 2 – 12f) or 0 – 14f) 2 x 2 – 12f) or2 x 0 – 14f) Redox valueRedox single-rod measuring cellmV 0 – 1000 2 x 0 – 1000 Conductivity conductiveConductivity measuring cell (k=1)mS/cm 0 – 2g), 0 – 20g) oder 0 – 100g) 2 x 0 – 2g), 0 – 20g) oder 0 – 100g) ChloriteDiaphragm-covered measuring cellmg/l 0 – 2e) - Hydrogen peroxideDiaphragm-covered measuring cellmg/l 0 – 200e) - TemperaturePt100°C 5 – 45 (standard version)5 – 60 (can be configured via the Matchcode ordering system) Output modules (depending on version) Number of output modules up to 4 2 x up to 4 Servomotor relay 2 x 230 V AC, 5 A (ohmic load) kΩ Potentiometer feedback: 1 – 10 Servomotor 20 mA Constant 0/4 – 20 mA output Servomotor with 20 mA feedback Relay 2 x 230 V AC, 5 A (ohmic load) Optocoupler 2 x 80 V DC, 5 mA Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-EASYPRO-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-EASYPRO-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-EASYPRO-Industrie-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-EASYPRO-industry-EN-PI.pdf
Your contact person
Lutz-JESCO America Corp.
Do you have questions about dosing pumps, disinfection systems, chlorine dosing systems, system and process technology or measurement and control technology?
Our team of experts will be happy to assist you. Please send us an enquiry or call us directly.
+1 5854260990
infoljac@lutzjescoamerica.com
