Flow meter accessories
Filter
Relay module RM10
for the ST10, SL10, VA10, HC10, HDO 250, HDO 400, HDO 500 series
Description:
The relay module enables volume preselection with the corresponding connection cables.
Voltage: 220 - 230V
Properties & advantages
Frequency: 50 - 60 Hz
Labelling: II (2) G [Ex ib Gb] IIC
Explosion protection
Stainless steel
1 1/4" - 1 1/4" IG
Drum pump connection
made of stainless steel for Flow meters VA 10 Ex
Description:
The drum pump connection is required to connect a VA 10 flow meter to a drum and container pump.
Material: Stainless steel
Properties & advantages
Connection: 1 1/4" female thread - 1 1/4" female thread to 1 1/4" male thread
Seals: PTFE PTFE
Connection cable: Motor/Slow 1-fold
for the RM10 relay module
Description:
The connection cable is used for direct connection between the RM10 relay module and the respective Motor:.
Special lengths are available on request
Properties & advantages
Cable length: 0.5 m
Voltage: 230 V
Frequency: 50 Hz
brass
Solenoid valve
for the RM10 / RM30 relay module
Description:
The 2/2-way solenoid valve seals off the air supply to the double diaphragm pump. It can be controlled via the relay module.
Material: brass / stainless steel / PVC
The Ex versions include the mini CLIX®/eXLink® plug and a 5 m connection cable
Properties & advantages
Seals: FPM / PTFE (Ex version)
Connection type: 3/4 "IG
Voltage: 230 V
Frequency: 50 Hz
PPO
1 1/4" FEMALE THREAD
FPM seal
Drum pump connection
made of plastic for Flow meters ST 10 and SL10
Description:
The drum pump connection is required to connect the ST 10 / SL10 flow meters to a drum and container pump. Connection: The PPS version of the conductive drum pump connection is required to connect the LM10 / UN 10 flow meters to a drum pump.
Materials PPO / PPS
Properties & advantages
Connections: 1 1/4" female thread to 2" male thread
Seals: FPM and FPM - FEP
Connection cable: Motor/Slow 3-way
for the RM10 relay module
Description:
The connection cable is used for direct connection between the RM10 relay module and the respective Motor:.
Special lengths are available on request
Properties & advantages
Cable length: 0.5 m
Voltage: 230 V
Frequency: 50 Hz
Connection cable slow valve
for the RM10 relay module
Description:
The connection cable is used for direct connection between the RM10 relay module and the slow valve.
Special lengths are available on request
Properties & advantages
Cable length: 5 m
Voltage: 230 V
Frequency: 50 Hz
Control unit
for series ST10, SL10, VA10, HDO080, HDO120, HDO200, HDO250, HDO400, HDO500
Description:
Evaluation electronics with touchscreen for operating the Flow meter. The operating unit is used to evaluate the pulses and shows them as a quantity on the digital display.
Types: BE 10 / BE 10V (encapsulated electronics)
PP
Combi plate
for the ST10, SL10, LM10, UN10, VA10, HDO 080, HDO 120; HDO 200, HDO 250, HDO 400, HDO 500 series
Description:
The combination plate is required to fix the operating unit. It can be used to fix the modules to the wall or as a heat protection plate between the base meter and the modules.
Material: Polypropylene (PP)
PTFE
Seal FPM
Non-return valve
for Flow meters ST10 / SL10
Description:
The non-return valve prevents the liquid from flowing back into the full hose system.
Material: PTFE
Properties & advantages
Seals: FPM / FPM-FEP
Opening pressure: 0.05 bar
Explosion protection
Control unit
for series ST10, SL10, VA10, HDO080, HDO120, HDO200, HDO250, HDO400, HDO500
Description:
Evaluation electronics with touchscreen for operating the Flow meter. The operating unit is used to evaluate the pulses and shows them as a quantity on the digital display.
Types: Ex-BE 10B / Ex-BE 10BV (electronics encapsulated)
Explosion protection
1 data socket
Protective cover
for the ST10, SL10, LM10, UN10, VA10, HDO 080, HDO 120; HDO 200, HDO 250, HDO 400, HDO 500 series
Description:
The protective cover enables and protects the modules for decentralised installation of the relay module and / or the operating unit.
1 data socket / 2 data sockets
Mains connection cable
for the RM30 relay module
Description:
The mains connection cable is used to connect the RM30 relay module.
Special lengths are available on request
Properties & advantages
Cable length: 5 m
Voltage: 400 V
Frequency: 50 Hz
5-pole
Explosion protection
Wall bracket set
for the ST10, SL10, LM10, UN10, VA10, HDO 080, HDO 120; HDO 200, HDO 250, HDO 400, HDO 500 series
Description:
The travelling bracket set is an additional bracket attachment. Installation is only possible together with a combination plate (0230-304).
for top-hat rails (TS 35) EN 50022
Ex-Schutz
230V
Relay module Ex-RM10mB (basic version)
for the LM10, UN10, VA10, HDO080Ex, HDO120Ex, HDO200Ex, HDO250Ex, HDO400Ex, HDO500Ex series
Description:
The relay module enables filling with volume preselection in hazardous areas. The Ex plug connections and accessories are not integrated. The basic version includes a 5m data cable and a 14-pin coupling plug.
Accessories available on request
Properties & advantages
Voltage: 120V or 230V
Frequency: 50 - 60 Hz
Labelling: II 2G Ex eb mb [ib] IIC T4 Gb
Explosion protection
Base counter
for type LM10
Description:
The basic meter is required for decentralised installation and external data evaluation. The individual modules (basic counter, operating unit, relay module, etc.) can be mounted separately from each other for larger distances between the measuring and control points or installation locations in the system that are difficult to access. Data transmission between the components is established without complicated wiring by means of plug connections via a data cable and a protective cover / pulse converter.
Material: PPS
Properties & advantages
Measuring chamber: LCP
Seals: FEP FEP
Magnet material: BaFE / MS / stainless steel (1.4401)
Type of protection: II 2G Ex h IIB Gb X
PP
Double nipple
in the PP version
Description:
The double nipple is required as a connection between the solenoid valve and hose connection.
Material: PP / brass / stainless steel
Properties & advantages
Connection type: 3/4" AG to 1 1/4" AG
Explosion protection
230V
Relay module Ex-RM10mK (complete version)
for the LM10, UN10, VA10, HDO080Ex, HDO120Ex, HDO200Ex, HDO250Ex, HDO400Ex, HDO500Ex series
Description:
The relay module enables filling with volume preselection in hazardous areas. The Ex plug connections and accessories are not integrated. The basic version includes a 5m data cable and a 14-pin coupling plug.
Accessories available on request
Properties & advantages
Voltage: 120V or 230V
Frequency: 50 - 60 Hz
Labelling: II 2G Ex de [ib Gb] IIC T6 Gb
3/4"
Hose holder
Description:
The hose holder makes it easy to attach open hose ends to drums and containers.
PPO
Seal FPM
1 1/4"
Threaded connection
made of plastic for Flow meters ST10 / SL10
Description:
The threaded connection connects the Flow meters with screw flanges or threaded fittings.
Material: PPO / PPS
Properties & advantages
Connection type: 1 1/4" AG
Seals: FPM and FPM - FEP
Explosion protection
Control unit
for the series for LM10, UN10, VA10, HDO080Ex, HDO120Ex, HDO200Ex, HDO250Ex, HDO400Ex, HDO500Ex
Description:
Evaluation electronics with touchscreen for operating the Flow meter. The operating unit is used to evaluate the pulses and shows them as a quantity on the digital display.
Types: Ex-BE10C / Ex-BE10CV (electronics encapsulated)
Extension cable
for the RM10 relay module
Description:
The extension cable is used to extend the connection on the RM10 relay module.
Special lengths are available on request
Properties & advantages
Cable length: 5 m
Voltage: 230 V
Frequency: 50 Hz
4-pole
2 Datenbuchsen
Impulsumwandler
for the ST10, SL10, VA10, HDO080, HDO120, HDO200, HDO250, HDO400, HDO500 series
Beschreibung:
Der Impulsumwandler verstärkt die Signale und wird benötigt wenn das nächste Modul mehr als 5 m entfernt ist. Der Signalverstärker wird auf den Basiszähler montiert.
1 Datenbuchse / 2 Datenbuchsen