Skip to main content

Flow meters TS Type VA10

Product information "Flow meters TS Type VA10"

Description:

The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures acids and alkalis, almost all solvents and highly flammable liquids precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with the quantity preselection (relay module) so that the Pump or the system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems.

  • Optional with volume preselection (relay module)
  • Examples of media: Hydrochloric acid, nitric acid, styrene, petrol, acetone etc.
  • Mobile on a Drum pump or with dispensing nozzle connection or stationary in plant construction

Properties & advantages

  • Measurement according to the wobble disc principle
  • High measuring accuracy
  • Variable display position: variable
  • Touchscreen display with self-explanatory, multilingual user interface
  • Measuring range (min. g/min) from 10 l/min to 100 l/min
  • simple operation
Connection: Thread
Design/Equipment: without volume preselection
Housing (Material): Stainless steel (1.4581/1.4571)
Inlet port (inch): 1 1/4"
Liquid temperature (max. °C): 80 (176,0 °F)
Magnet (Material): PTFE (polytetrafluoroethylene) encapsulated
Measuring accuracy calibrated**: ± 1%
Measuring chamber (Material): Stainless steel (1.4581/1.4571)
Measuring range (up to max. g/min): 100
Operating pressure (max. bar): from 8 bar
Outlet port (inch): 1 1/4"
Principle of measurement: Swash plate
Protection class: IP55
Seals (Material): FEP
Type: VA10
Viscosity (up to max. mPas)*.: 5000

* Die max. Fördermenge ist ein ermittelter Wert mittels Prüfstand und gemessen mit Wasser bei einer Mediumstemperatur von ca. 20° C. Die Messung erfolgt am Druckstutzen der Pumpe, ohne Schlauch, Zapfpistole oder Durchflussmesser. Die im Einsatz erzielbare Fördermenge ist niedriger und hängt von der individuellen Anwendung, den Medieneigenschaften sowie der Konfiguration der Pumpe ab. Die max. Förderhöhe ist ebenso abhängig von Pumpenausführung, Motor und Medium. Die Viskositätswerte werden mit Öl ermittelt.

** Prüfaufbau: Medium Wasser / Diesel, Durchfluss in Vorzugsrichtung, Beruhigungsstrecke 0,2 m vor und nach dem Durchflusszähler

Accessory Items

Swash plate
BATTERY
Communication module KM10K (complete version)
for non-flammable liquids
Description: The communication module enables communication with other control units. Cable glands are integrated Properties & advantages Analogue output (0-20mA, 4-20mA, 0-10V) Pulse and alarm output RS485 interface
Swash plate
BATTERY
Connection cable: Motor/Slow 1-fold
for non-flammable liquids
Description: The connection cable is used for direct connection between the RM10 relay module and the respective Motor:. Special lengths are available on request Properties & advantages Cable length: 0.5 m Voltage: 230 V Frequency: 50 Hz
Swash plate
BATTERY
Solenoid valve
for non-flammable liquids
Description: The 2/2-way solenoid valve seals off the air supply to the double diaphragm pump. It can be controlled via the relay module. Material: brass / stainless steel / PVC The Ex versions include the mini CLIX®/eXLink® plug and a 5 m connection cable Properties & advantages Seals: FPM / PTFE (Ex version) Connection type: 3/4 "IG Voltage: 230 V Frequency: 50 Hz
Swash plate
BATTERY
Relay module RM10
for non-flammable liquids
Description: The relay module enables volume preselection with the corresponding connection cables. Voltage: 220 - 230V Properties & advantages Frequency: 50 - 60 Hz Labelling: II (2) G [Ex ib Gb] IIC
Swash plate
BATTERY
NG10 power supply unit
for non-flammable liquids
Description: The power supply unit supplies power to the operating unit. When using a relay module, no additional power supply unit is required as the module contains the power supply function. Voltage: 220 - 230 V Properties & advantages Frequency: 50 - 60 Hz Labelling: II (2) G [Ex ib Gb] IIC
Swash plate
BATTERY
Mains connection cable
for non-flammable liquids
Description: The mains connection cable is used to connect the RM10 relay module / NG10 power supply unit and the Safety Box. Special lengths are available on request Properties & advantages Cable length: 5 m Voltage: 230 V Frequency: 50 Hz
Swash plate
BATTERY
Connection cable: main valve
for non-flammable liquids
Description: The connection cable is used for direct connection between the RM10 / RM30 relay module and the main valve. Special lengths are available on request Properties & advantages Cable length: 5 m Voltage: 230 V Frequency: 50 Hz
Swash plate
BATTERY
Control pen
for non-flammable liquids
Swash plate
BATTERY
Relay module RM30
for non-flammable liquids
Description: The relay module enables volume preselection with the corresponding connection cables. It is required to control Three-phase motors. Voltage: 230 V or 400 V Properties & advantages Power: 0.8 kW or 1.5 kW Frequency: 50 Hz Labelling: II (2) G [Ex ib Gb] IIC

Similar Items

Swash plate
BATTERY
Flow meter TS Type ST10
for non-flammable liquids
Description: The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures low-viscosity to medium-viscosity media such as water and mineral oils precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with a quantity preselector (relay module) so that the Pump or the system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems. Optional with volume preselection (relay module) Examples of media: Water, oil, diesel, heating oil, hydraulic oils, etc. Mobile on a Drum pump or with dispensing nozzle connection or stationary in plant construction Properties & advantages Measurement according to the wobble disc principle High measuring accuracy Variable display position: variable Touchscreen display with self-explanatory, multilingual user interface Measuring range (min. g/min) from 10 l/min to 100 l/min simple operation
Swash plate
BATTERY
Flow meter TS Type SL10
for non-flammable liquids
Description: The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures oils, aggressive media such as acids and alkalis precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with a quantity preselector (relay module) so that the Pump or the system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems. Optional with volume preselection (relay module) Examples of media: Hydrochloric acid, nitric acid, etc. Mobile on a Drum pump or with dispensing nozzle connection or stationary in plant construction Properties & advantages Measurement according to the wobble disc principle High measuring accuracy Variable display position: variable Touchscreen display with self-explanatory, multilingual user interface Measuring range (min. g/min) from 10 l/min to 100 l/min simple operation