Description:

The first flowmeter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures solvents, acids, alkalis, highly flammable liquids, oils and neutral media precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with the quantity preselection (relay module) so that the Pump or system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems.

  • Optional with volume preselection (relay module)
  • Media examples: Methanol, petrol, isopropanol, paraffin, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc.
  • Mobile on a Drum pump or with dispensing nozzle connection or stationary in plant construction

Properties & advantages

  • Measurement according to the wobble disc principle
  • High measuring accuracy
  • Variable display position: variable
  • Touchscreen display with self-explanatory, multilingual user interface
  • Measuring range (min/min) from 10 l/min to 100 l/min
  • approved according to ATEX Directive 2014/34/EU, Category 2
Certification: ATEX Directive (ATEX Directive 2014/34/EU)
Connection: Thread
Design/Equipment: without volume preselection
Explosion protection: Yes
Housing (Material): Stainless steel (1.4581/1.4571)
Inlet port (inch): 1 1/4"
Liquid temperature (max. °C): 60 (140,0 °F)
Magnet (Material): PTFE (polytetrafluoroethylene) encapsulated
Measuring accuracy calibrated**: ± 1%
Measuring chamber (Material): Stainless steel (1.4581/1.4571)
Measuring range (up to max. g/min): 100
Operating pressure (max. bar): from 8 bar
Outlet port (inch): 1 1/4"
Principle of measurement: Swash plate
Protection class: IP55
Seals (Material): FEP
Type: VA10 Ex
Viscosity (up to max. mPas)*.: 5000

* Die max. Fördermenge ist ein ermittelter Wert mittels Prüfstand und gemessen mit Wasser bei einer Mediumstemperatur von ca. 20° C. Die Messung erfolgt am Druckstutzen der Pumpe, ohne Schlauch, Zapfpistole oder Durchflussmesser. Die im Einsatz erzielbare Fördermenge ist niedriger und hängt von der individuellen Anwendung, den Medieneigenschaften sowie der Konfiguration der Pumpe ab. Die max. Förderhöhe ist ebenso abhängig von Pumpenausführung, Motor und Medium. Die Viskositätswerte werden mit Öl ermittelt.

** Prüfaufbau: Medium Wasser / Diesel, Durchfluss in Vorzugsrichtung, Beruhigungsstrecke 0,2 m vor und nach dem Durchflusszähler

Similar Items

Explosion protection
Swash plate
BATTERY
Flow meters TS Type LM10 Ex
for solvents, acids, alkalis and flammable liquids
Description: The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables accurate measurement of the volume flow and measures solvents and highly flammable liquids, oils and neutral media precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with the quantity preselection (relay module) so that the Pump or the system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems. Optional with volume preselection (relay module) Media examples: Methanol, petrol, isopropanol, paraffin, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc. Mobile on a Drum pump or with dispensing nozzle connection or stationary in plant construction Properties & advantages Measurement according to the wobble disc principle High measuring accuracy Variable display position: variable Touchscreen display with self-explanatory, multilingual user interface Measuring range (min/min) from 10 l/min to 100 l/min approved according to ATEX Directive 2014/34/EU, Category 2
Explosion protection
Swash plate
BATTERY
Flow meters TS Type UN10 Ex
for solvents, acids, alkalis and flammable liquids
Description: The first flowmeter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures solvents, acids, alkalis, highly flammable liquids, oils and neutral media precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with the quantity preselection (relay module) so that the Pump or system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems. Optional with volume preselection (relay module) Media examples: Methanol, petrol, isopropanol, paraffin, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc. Mobile on a Drum pump or with dispensing nozzle connection or stationary in plant construction Properties & advantages Measurement according to the wobble disc principle High measuring accuracy Variable display position: variable Touchscreen display with self-explanatory, multilingual user interface Measuring range (min/min) from 10 l/min to 100 l/min approved according to ATEX Directive 2014/34/EU, Category 2

Accessory Items

Explosion protection
Swash plate
BATTERY
Communication module KM10K (complete version)
for solvents, acids, alkalis and flammable liquids
Description: The communication module enables communication with other control units. Cable glands are integrated Properties & advantages Analogue output (0-20mA, 4-20mA, 0-10V) Pulse and alarm output RS485 interface
Explosion protection
Swash plate
BATTERY
Control pen
for solvents, acids, alkalis and flammable liquids
Explosion protection
Swash plate
BATTERY
Drum pump connection
for solvents, acids, alkalis and flammable liquids
Description: The drum pump connection is required to connect a VA 10 flow meter to a drum and container pump. Material: Stainless steel Properties & advantages Connection: 1 1/4" female thread - 1 1/4" female thread to 1 1/4" male thread Seals: PTFE PTFE
Explosion protection
Swash plate
BATTERY
Solenoid valve
for solvents, acids, alkalis and flammable liquids
Description: The 2/2-way solenoid valve seals off the air supply to the double diaphragm pump. It can be controlled via the relay module. Material: brass / stainless steel / PVC The Ex versions include the mini CLIX®/eXLink® plug and a 5 m connection cable Properties & advantages Seals: FPM / PTFE (Ex version) Connection type: 3/4 "IG Voltage: 230 V Frequency: 50 Hz
Explosion protection
Swash plate
BATTERY
Power supply unit Ex-NG10m
for solvents, acids, alkalis and flammable liquids
Description: The power supply unit supplies power to the operating unit. When using a relay module, no additional power supply unit is required as the module includes the power supply function. For direct applications in hazardous areas (Zone 1 & Zone 2) takes over the power supply for the complete flow meter system ##########. for frequent filling processes or continuous operation of the meters Can be retrofitted to existing meter systems using modular technology Properties & advantages Permanent power supply in hazardous areas Compact system possible due to mounting on basic meter No battery required in operating unit the power supply unit is supplied ready to plug in with 5 m connection cable and 3-pin Ex plug (CEAG) Frequency: 50 - 60 Hz