Product information "Flow meters TS Type UN10 Ex"
Description:
The first flowmeter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures solvents, acids, alkalis, highly flammable liquids, oils and neutral media precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with the quantity preselection (relay module) so that the Pump or system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems.
- Optional with volume preselection (relay module)
- Media examples: Methanol, petrol, isopropanol, paraffin, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc.
- Mobile on a Drum pump or with dispensing nozzle connection or stationary in plant construction
Properties & advantages
- Measurement according to the wobble disc principle
- High measuring accuracy
- Variable display position: variable
- Touchscreen display with self-explanatory, multilingual user interface
- Measuring range (min/min) from 10 l/min to 100 l/min
- approved according to ATEX Directive 2014/34/EU, Category 2
Certification: | ATEX Directive (ATEX Directive 2014/34/EU) |
---|---|
Connection: | Thread |
Design/Equipment: | without volume preselection |
Explosion protection: | Yes |
Housing (Material): | PPS (polyphenylene sulphide) |
Inlet port (inch): | 2" |
Liquid temperature (max. °C): | 60 (140,0 °F) |
Magnet (Material): | PPS (polyphenylene sulphide) encapsulated |
Measuring accuracy calibrated**: | ± 1% |
Measuring chamber (Material): | LCP |
Measuring range (up to max. g/min): | 100 |
Operating pressure (max. bar): | 4 |
Outlet port (inch): | 1 1/4" |
Principle of measurement: | Swash plate |
Protection class: | IP55 |
Seals (Material): | FEP |
Type: | UN10 Ex |
Viscosity (up to max. mPas)*.: | 2000 |
* Die max. Fördermenge ist ein ermittelter Wert mittels Prüfstand und gemessen mit Wasser bei einer Mediumstemperatur von ca. 20° C. Die Messung erfolgt am Druckstutzen der Pumpe, ohne Schlauch, Zapfpistole oder Durchflussmesser. Die im Einsatz erzielbare Fördermenge ist niedriger und hängt von der individuellen Anwendung, den Medieneigenschaften sowie der Konfiguration der Pumpe ab. Die max. Förderhöhe ist ebenso abhängig von Pumpenausführung, Motor und Medium. Die Viskositätswerte werden mit Öl ermittelt.
** Prüfaufbau: Medium Wasser / Diesel, Durchfluss in Vorzugsrichtung, Beruhigungsstrecke 0,2 m vor und nach dem Durchflusszähler