Skip to main content

Flow meters HDO 500 Niro/PPS

Product information "Flow meters HDO 500 Niro/PPS"

Description:

The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating Oval gear meters and the magnets placed on the measuring wheels, it enables accurate measurement of the volume flow and measures non-flammable liquids such as alkalis, mineral oils, hydrocarbons and solvents as well as highly flammable liquids precisely, quickly and, above all, efficiently.

  • Explosion proof version available as an option
  • Examples of media: Paints, varnishes, acids, alkalis, mineral oils, solvents

Properties & advantages

  • Measurement according to the oval gear principle
  • High measuring accuracy due to overrun correction
  • Low pressure losses in the system
  • Touchscreen display with self-explanatory, multilingual user interface
  • Relay module for volume preselection can be retrofitted at any time
  • Approved in accordance with ATEX Directive 2014/34/EU, Category 2
Connection: Flange
Design/Equipment: without volume preselection
Explosion protection: No
Flange connection (PN): 16
Housing (Material): Stainless steel (1.4404)
Liquid temperature (max. °C): 80 (176,0 °F)
Measuring accuracy calibrated**: ± 1%
Measuring range (up to max. g/min): Flow volumes up to 100 GPM
Measuring wheels (Material): PPS (polyphenylene sulphide)
Nominal diameter (DN): 50
Operating pressure (max. bar): 16
Principle of measurement: Oval wheel
Protection class: IP55
Repeatability (%): ± 0,03
Seals (Material): FPM (fluororubber)
Shaft (Material): Stainless steel (1.4404)
Type: HDO 500 Niro/PPS
Viscosity (up to max. mPas)*.: 1000

* Die max. Fördermenge ist ein ermittelter Wert mittels Prüfstand und gemessen mit Wasser bei einer Mediumstemperatur von ca. 20° C. Die Messung erfolgt am Druckstutzen der Pumpe, ohne Schlauch, Zapfpistole oder Durchflussmesser. Die im Einsatz erzielbare Fördermenge ist niedriger und hängt von der individuellen Anwendung, den Medieneigenschaften sowie der Konfiguration der Pumpe ab. Die max. Förderhöhe ist ebenso abhängig von Pumpenausführung, Motor und Medium. Die Viskositätswerte werden mit Öl ermittelt.

** Prüfaufbau: Medium Wasser / Diesel, Durchfluss in Vorzugsrichtung, Beruhigungsstrecke 0,2 m vor und nach dem Durchflusszähler

Accessory Items

Flange
Oval wheel
##########_0__ mPas
Relay module Ex-RM10dK (complete version)
for non-flammable liquids
Description: The relay module enables filling with volume preselection in hazardous areas. The Ex plug-in connections according to the mini CLIX®/eXLink® system are integrated. The complete version includes a 5 m connection cable with 3-pin Ex plug (CEAG). Voltage: 220 - 230V Properties & advantages Frequency: 50 - 60 Hz Labelling: II 2G Ex de [ib Gb] IIC T6 Gb
Flange
Oval wheel
##########_0__ mPas
Relay module RM30
for non-flammable liquids
Description: The relay module enables volume preselection with the corresponding connection cables. It is required to control Three-phase motors. Voltage: 230 V or 400 V Properties & advantages Power: 0.8 kW or 1.5 kW Frequency: 50 Hz Labelling: II (2) G [Ex ib Gb] IIC
Flange
Oval wheel
##########_0__ mPas
Communication module KM10K (complete version)
for non-flammable liquids
Description: The communication module enables communication with other control units. Cable glands are integrated Properties & advantages Analogue output (0-20mA, 4-20mA, 0-10V) Pulse and alarm output RS485 interface
Flange
Oval wheel
##########_0__ mPas
Connection cable: Motor/Slow 1-fold
for non-flammable liquids
Description: The connection cable is used for direct connection between the RM10 relay module and the respective Motor:. Special lengths are available on request Properties & advantages Cable length: 0.5 m Voltage: 230 V Frequency: 50 Hz
Flange
Oval wheel
##########_0__ mPas
Control pen
for non-flammable liquids
Flange
Oval wheel
##########_0__ mPas
Relay module RM10
for non-flammable liquids
Description: The relay module enables volume preselection with the corresponding connection cables. Voltage: 220 - 230V Properties & advantages Frequency: 50 - 60 Hz Labelling: II (2) G [Ex ib Gb] IIC
Flange
Oval wheel
##########_0__ mPas
Relay module Ex-RM10dB (basic version)
for non-flammable liquids
Description: The relay module enables filling with volume preselection in hazardous areas. The Ex plug connections and accessories are not integrated. The basic version includes a 5m data cable and a 14-pin coupling plug. Accessories available on request Properties & advantages Voltage: 220 - 230V Frequency: 50 - 60 Hz Labelling: II 2G Ex de [ib Gb] IIC T6 Gb
Flange
Oval wheel
##########_0__ mPas
NG10 power supply unit
for non-flammable liquids
Description: The power supply unit supplies power to the operating unit. When using a relay module, no additional power supply unit is required as the module contains the power supply function. Voltage: 220 - 230 V Properties & advantages Frequency: 50 - 60 Hz Labelling: II (2) G [Ex ib Gb] IIC
Flange
Oval wheel
##########_0__ mPas
Mains connection cable
for non-flammable liquids
Description: The mains connection cable is used to connect the RM10 relay module / NG10 power supply unit and the Safety Box. Special lengths are available on request Properties & advantages Cable length: 5 m Voltage: 230 V Frequency: 50 Hz
Flange
Oval wheel
##########_0__ mPas
Connection cable: main valve
for non-flammable liquids
Description: The connection cable is used for direct connection between the RM10 / RM30 relay module and the main valve. Special lengths are available on request Properties & advantages Cable length: 5 m Voltage: 230 V Frequency: 50 Hz
Flange
Oval wheel
##########_0__ mPas
Power supply unit Ex-NG10m
for non-flammable liquids
Description: The power supply unit supplies power to the operating unit. When using a relay module, no additional power supply unit is required as the module includes the power supply function. For direct applications in hazardous areas (Zone 1 & Zone 2) takes over the power supply for the complete flow meter system ##########. for frequent filling processes or continuous operation of the meters Can be retrofitted to existing meter systems using modular technology Properties & advantages Permanent power supply in hazardous areas Compact system possible due to mounting on basic meter No battery required in operating unit the power supply unit is supplied ready to plug in with 5 m connection cable and 3-pin Ex plug (CEAG) Frequency: 50 - 60 Hz

Similar Items

Flange
Oval wheel
##########_0__ mPas
Flow meters HDO 500 Niro/Niro
for non-flammable liquids
Description: The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating Oval gear meters and the magnets placed on the measuring wheels, it enables accurate measurement of the volume flow and measures non-flammable liquids such as alkalis, mineral oils, hydrocarbons and solvents as well as highly flammable liquids precisely, quickly and, above all, efficiently. Explosion proof version available as an option Examples of media: Paints, varnishes, acids, alkalis, mineral oils, solvents Properties & advantages Measurement according to the oval gear principle High measuring accuracy due to overrun correction Low pressure losses in the system Touchscreen display with self-explanatory, multilingual user interface Relay module for volume preselection can be retrofitted at any time Approved in accordance with ATEX Directive 2014/34/EU, Category 2
Flange
Oval wheel
##########_0__ mPas
Flow meters HDO 500 Alu/PPS
for non-flammable liquids
Description: The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating Oval gear meters and the magnets placed on the measuring wheels, it enables accurate measurement of the volume flow and measures non-flammable liquids such as alkalis, mineral oils, hydrocarbons and solvents as well as highly flammable liquids precisely, quickly and, above all, efficiently. Explosion proof version available as an option Examples of media: Paints, varnishes, acids, alkalis, mineral oils, solvents Properties & advantages Measurement according to the oval gear principle High measuring accuracy due to overrun correction Low pressure losses in the system Touchscreen display with self-explanatory, multilingual user interface Relay module for volume preselection can be retrofitted at any time Approved in accordance with ATEX Directive 2014/34/EU, Category 2