Skip to main content

Warm water disinfection and cold water circuits with chlorine dioxide (ClO2)

To the products

Medical and other public facilities that supply drinking water to third parties, the food industry and the animal husbandry industry require high-quality drinking water as the prerequisite to correct operation. The heating of drinking water in circulating warm water lines with multiple branches requires the dosing of a disinfectant with a depot effect. This successfully combats, kills and inactivates Legionella and other pathogens in drinking water and prevents them from multiplying.

This is where chlorine dioxide comes into play – a powerful disinfectant that works effectively to eliminate pathogens and stops them from multiplying. Unlike some other chemicals, chlorine dioxide is not suitable for storage and must therefore be produced directly on site and dosed into the water circuit from basic chemicals as required. This is performed safely and precisely using special chlorine dioxide systems that satisfy the latest and strictest standards.

These systems, in combination with advanced measurement and control technology, form a complete disinfection system that will work independently and reliably for years. In addition to public facilities, Lutz-Jesco products are also used in animal husbandry, aquaria and even in the provision of a drinking water supply in sports facilities, for example in showers.

Suitable products for your application

TOPAX® MC
Description:Zuverlässig und individuell Mit der EASYPRO erhalten Sie ein komplett auf Ihre Bedürfnisse abgestimmtes System zur Überwachung und Regelung verschiedener Wasserparameter in Ihrem Schwimmbad. Durch den auf der EASYPRO verbauten Mehrkanalregler TOPAX® MC werden die Wasserparameter kontinuierlich gemessen und im Sollbereich gehalten. Er bietet die Möglichkeit eine Vielzahl von Aktoren und Stellgliedern anzusteuern und zeichnet sich durch seine sehr einfache und intuitive Bedienung aus. Die mehrfarbigen LEDs sorgen für eine optische Warnung, wenn die Wasserparameter den Sollbereich verlassen. -->Features & advantages: At a glance Modular structure of the inputs and outputs Up to four sensors and additionally up to four temperature sensors Freely-configurable overviews Difference value measurement (e.g. ΔpH) Graphical display of the deviation from the desired setpoint Up to four reference sets can be configured and loaded via a digital input or time control Service entries and sensor change can be saved Limit value control (can be used as a DIN contact for partial load operation in accordance with DIN 19643) 1 – 9 potential-free relay outputs Web server and Modbus protocol via Ethernet Trend Display Large colour touch-display Data is saved on a USB flash drive TOPAX® MC Housing dimensions (W x H x D)mm 302 x 240 x 107 Voltage supply 100 – 240 V AC, 50/60 Hz Power consumptionW max. 20 Analogue outputs for remote transmission 4 x 0/4 – 20 mA, working resistance max 500 Ω Disturbance variable inputmA 0/4 – 20 Interfaces Ethernet TCP/IP or RS485 Modbus RTU (optional) Protection class IP65 Ambient temperature°C -5 to +45 (no exposure to direct sunlight) Control characteristic P, PI, PID or PD behaviour, control direction selectable with disturbance variable feed forward, 2-side control selectable Measuring inputs (depending on version) Number of measuring inputs up to 4* Free chlorineAmperometric 3-electrode measuring cell with potentiostat (DMZ3.1)mg/l 0 – 15 (dependant on the measuring cell transconductance) CS120 excess chlorine measuring cellmg/l 0 – 10 (dependant on the measuring cell transconductance) Diaphragm-covered measuring cellmg/l 0 – 2 or 0 – 10(dependant on the measuring cell) Chlorine dioxideAmperometric 3-electrode measuring cell with potentiostat (DMZ3.1)mg/l 0 – 15 (dependant on the measuring cell transconductance) CS120 excess chlorine measuring cellmg/l 0 – 10 (dependant on the measuring cell transconductance) Diaphragm-covered measuring cellmg/l 0 – 2(dependant on the measuring cell) Total chlorineDiaphragm-covered measuring cellmg/l 0 – 10 (dependant on the measuring cell) pH valuepH single-rod measuring cellpH 0 – 14 (dependant on the single-rod measuring chain) Redox valueRedox single-rod measuring cellmV 0 – 1000 (dependant on the single-rod measuring chain) Conductivity conductiveConductivity measuring cell (k=1)mS/cm 0 – 2, 0 – 20 or 0 – 100(Depending on the configuration, corresponds to approx. 0 – 1 % or 0 – 5 % salt content) TemperaturePt100°C -10 bto +90 5 – 60 (configurable) Output modules (depending on version) Servomotor relay 2 x 230 V AC, 5 A (ohmic resistive load) kΩ Potentiometer feedback: 1 – 10 Servomotor 20 mAmA Constant 0/4 – 20 mA output Servomotor with 20 mA feedback Relays 2 x 230 V AC, 5 A (ohmic resistive load) Optocoupler 2 x 80 V DC, 5 mA Downloadshttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-TOPAX_MC-DE-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/pg4/LJ-TOPAX_MC-EN-BA.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-TOPAX-MC-DE-PI.pdfhttps://www.lutzjescoamerica.com/fileadmin/data/dokumente/produktinfos/LJ-TOPAX-MC-EN-PI.pdf
Your contact person
Lutz-JESCO America Corp.
Do you have questions about dosing pumps, disinfection systems, chlorine dosing systems, system and process technology or measurement and control technology?
Our team of experts will be happy to assist you. Please send us an enquiry or call us directly.
+1 5854260990