Skip to main content Skip to search Skip to main navigation
Go to homepage

Vacuum regulator C 2214

Product information "Vacuum regulator C 2214"

The C 2214 is designed for individual operation. For use on gas drums, a heated droplet separator is optionally available on the pressure side in the inlet valve of the C 2214. A safety blow-off valve is integrated and prevents an impermissible increase in pressure in the downstream vacuum line system. The quantity of gas dosed can be optimally adjusted on the C 2214 using a dosing valve and flow meter.

Features & advantages

  • Throughput capacity with chlorine gas: up to 4 kg/h
  • Residual pressure protection: Prevents the chlorine cylinder from being completely evacuated to prevent corrosion caused by moisture in the air
  • Filter: To protect the valve from dirt particles from the chlorine cylinder or the connection area
  • Cylinder pressure gauge: For displaying the pressure in the chlorine tank
  • Integrated safety blow-off valve
  • Flow meter with manual setting
  • Gas filter
  • Compact design
  • Available with all standard gas connections
MATCHCODE: 0204V81N1N9900L0A
Functions::: The Vacuum regulator is used to reduce the gas pressure from the
Type: C 2214
Input::: YOKE - CGA V-1 [820]
Dosing connection: Hose clamp connection 8/12
Blow-off connection::: Hose clamp connection 8/12
Flow meter:: without, max. flow capacity: 4 kg/h
Medium:: Chlorine gas
Pressure gauge::: without
Residual pressure protection::: 0.1 bar
Function-2: Overpressure of the gas containers to negative pressure [Vacuum].
Function-3: When the operating vacuum is removed, the inlet valve closes and
Function-4: prevents the flow.
Function-5: Suitable for dry chlorine gas [purity > 99.5%].