Vacuum regulator C 2213
Product number:
20401332
Product information "Vacuum regulator C 2213"
The C 2213 is designed for both individual and parallel use of several vacuum regulators in battery operation. A heated droplet separator is optionally available for use on gas drums on the pressure side.
Features & benefits
- Throughput capacity with chlorine gas: up to 10 kg/h
- Residual pressure protection: Prevents the chlorine cylinder from being completely evacuated to prevent corrosion caused by moisture in the air
- Filter: To protect the valve from dirt particles from the chlorine cylinder or the connection area
- Cylinder pressure gauge: To display the pressure in the chlorine tank
- Simultaneous withdrawal: For largely uniform chlorine withdrawal from several chlorine cylinders in battery operation
- Flow limiter: To prevent cylinder icing due to excessive chlorine withdrawal
- Gas filter
- Compact design
- Available with all standard gas connections
| MATCHCODE: | 0204D81R0010L0A |
|---|---|
| Functions::: | The Vacuum regulator is used to reduce the gas pressure from the |
| Type: | C 2213 |
| Input::: | YOKE - CGA V-1 [820] |
| Dosing connection: | Hose clamp connection 12/16 |
| max. flow capacity::: | 10 kg/h |
| Medium:: | Chlorine gas |
| Pressure gauge::: | without |
| Residual pressure protection::: | 0.1 bar |
| Function-2: | Overpressure of the gas containers to negative pressure [Vacuum]. |
| Function-3: | When the operating vacuum is removed, the inlet valve closes and |
| Function-4: | prevents the flow. |
| Function-5: | Suitable for dry chlorine gas [purity > 99.5%]. |