Skip to main content Skip to search Skip to main navigation
Go to homepage

Pump tube B200 PVDF

Product information "Pump tube B200 PVDF"

Description:

The horizontal pumping unit is suitable for emptying highly aggressive, aqueous to slightly viscous media from IBC containers or tanks and is the perfect alternative to vertical drum pumps.
Perfectly suited for the removal of concentrated acids and alkalis
.

  • Optionally with leakage detection (safety box)
  • Horizontal connection at the bottom of the container
  • IBC connection: S60 x 6

Features & benefits

  • Optionally with electric or compressed air drive
  • Low loss of medium when disconnecting
  • Simple installation
  • Easy to dismantle
  • Small space requirement
  • Automatic emergency stop function of the motor when leakage is detected
Bearings (Material): ETFE / PTFE
Delivery head (up to max. m wc)*.: 16
Density (up to kg/dm³): 2,8
Design/Equipment: Without leakage detection
Flow rate (up to max. l/min)*.: 216
Immersion tube diameter (max. mm): 41
Impeller (Material): ETFE (ethylene tetrafluoroethylene copolymer)
Liquid temperature (max °C): 100
Mechanical seal (Material): Carbon, SiC, FPM, HC-4 (2.4610)
Pump tube material (Material): PVDF (polyvinylidene fluoride)
Static seal (Material): FPM (fluororubber)
Suitable fluids: Bromic acid, Dimethyl phthalate, Hydrofluoric acid, Nitric acid, Potassium bromate, Sulphuric acid
Type: B200 PVDF 41-R-GLRD
Type of impeller / Drive type: Rotor (axial conveyor wheel)
Type of seal: Mechanical seal: (GLRD)
Viscosity (up to max. mPas)*.: 1000

When selecting the appropriate drive type for a Pump tube, the question often arises in practice as to whether an impeller or a rotor should be used. The decision depends largely on the hydraulic requirements of the specific application.

Application 1: High delivery pressure and greater delivery heads required

Requirement
If long hose or pipe runs need to be overcome, the fluid has increased Viscosity or density, or higher overall pressure losses occur, a greater delivery head is required.

Typical influencing factors are:

  • Long hose lengths
  • Viscous or heavy fluids
  • Required pressure build-up in the system

Recommended solution
Impeller (L) = Radial impeller

The impeller is designed for applications where a stable pressure build-up is required. The pump tube thus enables reliable delivery even with increased resistance in the system and ensures a constant delivery capacity under demanding operating conditions.

Application 2: High flow rate with free discharge

Requirement
Where there is a free discharge and no significant Pressure losses in the delivery system, the priority is often to achieve the highest possible flow rate.

Typical influencing factors are:

  • Short hose lengths
  • Low flow resistance
  • Focus on flow rate rather than delivery head

Recommended solution
Rotor (R) = Axial impeller

The rotor is designed for maximum flow rates at minimum back pressure. It is ideal for applications with a free outlet where large flow rates need to be delivered efficiently and economically.

Conclusion:
The choice between an impeller and a rotor depends primarily on the hydraulic requirements of the application. For higher pressure requirements and greater delivery heads, the impeller is the appropriate solution. For free discharge and where high flow rates are required, the rotor is recommended.

When selecting a Pump tube, the correct seal type depends primarily on the properties of the pumped medium. The decisive factor is whether the medium is prone to deposits, crystallisation, sticking or hardening.

Pump tube with mechanical seal (GLRD)

Pump tubes with mechanical seals are the preferred choice when pumping media that are prone to crystallisation, sticking, hardening or spoilage. The mechanical seal prevents the pumped medium from entering the shaft guide tube. This reduces the risk of deposits and prevents the Drive shaft from seizing.

A further advantage is the simplified cleaning and flushing of the pump tube, particularly with demanding or changing media.

During operation, a thin lubricating film formed from the pumped medium develops between the sliding surfaces of the Mechanical seal. For this reason, dry running must be avoided at all costs, as this can lead to rapid wear or damage to the seal.

Recommended for:

  • crystallising media
  • sticky or hardening liquids
  • perishable pumped media
  • applications with increased cleaning and flushing requirements

Seal-less pump tube (DL)

Seal-less Pump tubes are suitable for all applications where the pumped medium does not cause critical deposits or scaling. As there is no mechanical seal, these pump tubes have a simpler design and are less sensitive to brief periods of dry running.

Brief dry running does not usually cause immediate damage to the pump tube. Nevertheless, dry running should always be avoided to prevent unnecessary wear and to maximise the Pump’s service life. Operation should therefore always be supervised.

Recommended for:

  • non-critical, clean or low-viscosity media
  • Applications with no tendency to form deposits
  • Applications with the possibility of short-term dry running

Conclusion:

If the pumped medium is prone to crystallisation, sticking, hardening or spoilage, a pump tube with a mechanical seal should generally be used. In all other standard pumping applications, a seal-less pump tube is usually the appropriate choice.

Skip product gallery

Accessory Items

horizontal
LUTZ Elektrische Containerpumpe B200 Niro, IBC Pumpe für Bodenablauf des Containers
Pump tube B200 Niro*
for concentrated acids and alkalis
Description: The horizontal pumping unit is suitable for emptying aqueous and fatty foodstuffs from IBC containers or tanks and is the perfect alternative to vertical drum pumps. Depending on the application, various motors are available that you can combine with the pumping unit at any time. This gives you flexibility at all times and saves important resources. Horizontal connection at the bottom of the container Pumping unit equipped with Lutz Original handwheel Also for alcoholic foods, cosmetics and pharmaceutical products as well as flammable cleaning agents Features & benefits Optionally with electric or compressed air drive Low loss of medium when disconnecting Food-safe connections Small space requirement Approved according to FDA and Regulation (EC) 1935/2004
horizontal
LUTZ Elektrische Containerpumpe B200 Niro, IBC Pumpe für Bodenablauf des Containers
Pump tube B200 Niro*
for concentrated acids and alkalis
Description: The horizontal pumping unit is suitable for emptying highly aggressive, low-viscosity, flammable and explosive liquids from IBC containers or tanks and is the perfect alternative to vertical drum pumps. Depending on the application, various motors are available that you can combine with the pumping unit at any time. This gives you flexibility at all times and saves important resources. Horizontal connection at the bottom of the container Pumping unit equipped with Lutz Original handwheel Suitable for emptying alternative fuels, oils and flammable liquids Features & advantages Optionally with electric or compressed air drive Low loss of medium when disconnected Explosion-proof versions for applications in hazardous areas(Zone 1 and 2) Easy to dismantle Small space requirement
horizontal
LUTZ Elektrische Containerpumpe B200 Niro, IBC Pumpe für Bodenablauf des Containers
Pump tube B200 Niro*
for concentrated acids and alkalis
Description: The horizontal pumping unit is suitable for emptying aqueous and fatty foodstuffs from IBC containers or tanks and is the perfect alternative to vertical drum pumps. Depending on the application, various motors are available that you can combine with the pumping unit at any time. This gives you flexibility at all times and saves important resources. Horizontal connection at the bottom of the container Pumping unit equipped with Lutz Original handwheel Also for alcoholic foods, cosmetics and pharmaceutical products as well as flammable cleaning agents Features & benefits Optionally with electric or compressed air drive Low loss of medium when disconnecting Food-safe connections Small space requirement Approved in accordance with ATEX Directive 2014/34/EU, category 1/2 Approved according to FDA and Regulation (EC) 1935/2004
Skip product gallery

Accessory Items

horizontal
Dispensing nozzle PVDF
Dispensing nozzle PVDF
for concentrated acids and alkalis
Description: For filling and decanting concentrated acids and alkalis. The housing and the valve plug of the dispensing nozzle are made of polyvinylidene fluoride (PVDF) and are equipped with a protective bracket and two outlet nozzles(Ø 23 mm and Ø 12mm). The dispensing nozzle is sealed with an FPM seal. FFPM or FEP / FPM seals are available at extra cost on request Connection: external thread G 1 1/4" Optionally available as a variant with a push-button for direct operation of the relay module (no communication module required) Features & benefits Simple adjustment of the volume flow Easy to operate Safe filling and Decanting the respective liquid
horizontal
Hose set for concentrated alkalis and acids
Hose set for concentrated alkalis and acids
for concentrated acids and alkalis
Description: The hose set is for concentrated alkalis + acids. The set is FDA and USP Class VI compliant. The set is used to connect to the pumping station or the dispensing nozzle. Also available in special lengths on request Suitable for filling or decanting chemicals, foodstuffs and hygiene products Features & advantages Nominal diameter DN 19 (3/4") PVDF hose connection Pre-assembled hose connections and hose clamps
horizontal
SPANNSCHLOSS
SPANNSCHLOSS
for concentrated acids and alkalis
Description: The turnbuckle relieves the outlet nozzle when using heavy motors.
horizontal
HOLDER
HOLDER
for concentrated acids and alkalis
Description: The bracket relieves the discharge spout when using heavy motors if the turnbuckle cannot be used.