Dosing head ventilation V
Trouble-free dosing of outgasing media
The dosing head ventilation V stands for trouble-free dosing of outgassing media. An automatic vent valve separates incoming gases, thereby enabling the independent re-aspiration of the pump given back pressure.
The dosing head ventilation can simply be replaced by the conventional dosing head from Lutz-Jesco MAGDOS dosing pumps sizes 05 – 15.
Dosing head ventilation V
- Can be fitted to all MAGDOS dosing pumps sizes 05 – 15
- Capacity range of the dosing pump with dosing head ventilation V
0.39 – 13 l/h, up to 16 bar - Easy to assemble
- High chemical resistance
- Transparent PMMA dosing head
- PVC valves and connections
Further product views
Dosing head ventilation V for MAGDOS sizes | 05 | 1 | 2 | 4 | 6 | 10 | 15 | ||
---|---|---|---|---|---|---|---|---|---|
Delivery capacity at max. backpressure | l/h | 0.30 | 0.63 | 1.60 | 3.10 | 5.10 | 7.30 | 11.00 | |
ml/stroke | 0.04 | 0.17 | 0.29 | 0.47 | 0.68 | 0.73 | |||
Maximum delivery pressure | Normal mode | bar | 16 | 8 | 6 | 3 | |||
Eco-Mode 1* | bar | 10 | 6 | 4 | 2 | ||||
Eco-Mode 2* | bar | 6 | 4 | 2 | 1 | ||||
Delivery capacity at average backpressure | l/h | 0.39 | 0.81 | 1.90 | 3.50 | 5.90 | 8.00 | 13.00 | |
ml/stroke | <0.05 | 0.20 | 0.33 | 0.54 | 0.74 | 0.86 | |||
Average delivery pressure | bar | 8 | 4 | 3 | 1 | ||||
Max. viscosity | mPa∙s | 20 | |||||||
Materials | Housing, valves | PMMA, PVC | |||||||
Seals | FPM or EPDM | ||||||||
Further components coming into contact with the media | PVDF, ceramic, Hastelloy | ||||||||
Approved ambient temperature | °C | 5 – 40 | |||||||
Approved media temperature | °C | 35 |
Subject to technical changes
BA: Operation instruction
PI: Product information