Water sampling station EASYPRO CS
Reliable and individual
With the EASYPRO CS, Lutz-Jesco offers a flexibly configurable system, which is based on the classic open amperometric disinfection measurement with the CS120.
The configuration flexibility means that a customised, very robust solution can be put together for your swimming pool or industrial application, which in the end saves costs because only the most necessary components are installed. .
The design of the base plate allows the CS120 to be used in combination with up to 3 other measurands in the water.
The TOPAX® MC multi-channel controller installed* in the EASYPRO CS subjects the water parameters to constant measurement, keeping them within the target range. It enables you to control a large number of actuators and permits easy and intuitive operation.
- TOPAX® MC multi-channel controller
- Measuring cells and measuring cell fittings
- Sample water filter
- Flow control
- Flow controller DFR 45 with sampling water extraction point and installed temperature sensor
- Inflow and outflow tap
- Bracket for buffer solutions and buffer solutions for adjusting the measuring cells
- Multi-coloured LEDs
- The measuring cells are partially packaged separately and not pre-installed.
EASYPRO CS components (fitted on the baseplate)
More product views
EASYPRO CS | CS 2 | CS 3 | CS 4 | Sample water requirement | for CS120 excess chlorine measuring cell | l/h | 45 approx. | |||
---|---|---|---|---|---|---|---|---|---|---|
with all other measuring cells | l/h | - | ||||||||
Sample water inflow and discharge | mm | PE hose 6/8 + stop valve with G1/4 connection | Pressure resistance | for diaphragm-covered measuring cell | bar | max. 6, air gap required | ||||
for all other measuring cells | l/h | max. 6 | ||||||||
Pressure loss in the water sampling station | bar | 0.3 approx. | ||||||||
Mesh size sample water filter | μm | 300 | ||||||||
Voltage supply | 100 – 240 V AC, 50/60 Hz | |||||||||
Power consumption | W | max. 20 | ||||||||
Analogue outputs for remote transmission | 4 x 0/4 – 20 mA, working resistance max. 500 | |||||||||
Disturbance variable input | mA | 0/4 – 20 | ||||||||
Interfaces | Ethernet TCP/IP or RS485 Modbus RTU (optional) | |||||||||
Protection class | IP65 (electronic controller) | |||||||||
Ambient temperature | °C | -5 to +45 (no exposure to direct sunlight) | ||||||||
Control characteristic | P, PI, PID or PD behaviour, control direction selectable with disturbance variable feed forward, 2-side control selectable | |||||||||
Measuring inputs (depending on version) | ||||||||||
Number of measuring inputs | 2a | 3b | 4c | |||||||
Bromine | Diaphragm-covered measuring cell | mg/l | 0 – 5e | |||||||
Free chlorine | Amperometric 3-electrode measuring cell with potentiostat (DMZ3.1) | mg/l | - | |||||||
CS120 excess chlorine measuring cell | mg/l | 0 – 10d) | ||||||||
Diaphragm-covered measuring cell | mg/l | - | ||||||||
Chlorine dioxide | Amperometric 3-electrode measuring cell with potentiostat (DMZ3.1) | mg/l | - | |||||||
CS120 excess chlorine measuring cell | mg/l | 0 – 10d) | ||||||||
Diaphragm-covered measuring cell | mg/l | - | ||||||||
Total chlorine | Diaphragm-covered measuring cell | mg/l | 0 – 10e | |||||||
Ozone | Diaphragm-covered measuring cell | mg/l | 0 – 2e | |||||||
pH value | pH single-rod measuring cell | pH | 2 – 12d or 0 – 14d | |||||||
Redox value | Redox single-rod measuring cell | mV | 0 – 1000 | |||||||
Conductivity conductive | Conductivity measuring (k=1) | mS/cm | 0 – 100g | |||||||
Chlorite | Diaphragm-covered measuring cell | mg/l | 0 – 2e | |||||||
Hydrogen peroxide | Diaphragm-covered measuring cell | mg/l | 0 – 200e | |||||||
Temperature | Pt100 | °C | 5 – 45 (standard version) | |||||||
Output modules (depending on version) | ||||||||||
Number of output modules | up to 4 | |||||||||
Servomotor relay | 2 x 230 V AC, 5 A (ohmic load) | |||||||||
kΩ | Potentiometer feedback: 1 – 10 | |||||||||
Servomotor 20 mA | Constant 0/4 – 20 mA output | |||||||||
Servomotor with 20 mA feedback | ||||||||||
Relays | 2 x 230 V AC, 5 A (ohmic load) | |||||||||
Optocoupler | 2 x 80 V DC, 5 mA | |||||||||
Relais High Current | 2 x 230 V AC, 8 A (ohmic load) |
a) a temperature sensor can also be connected
b) additionally, up to two temperature sensors can be connected
c) additionally, up to three temperature sensors can be connected
d) dependant on the measuring cell transconductance)
e) dependant on the measuring cell
f) dependant on the single-rod measuring cell
g) depending on the configuration, corresponds to approx. 0 – 1 % or 0 – 5 % salt content
technical modifications reserved
-